Applications & Case Studies

Chemical and Pharmaceutical

Emission Source

Pollutants Removed

Process Reactors All inorganic and most VOC compounds both particulate and gaseous.
Emergency Vents All inorganic and most VOC compounds both particulate and gaseous
Storage Tanks All inorganic and most VOC compounds both particulate and gaseous.
Product Dryers All inorganic and most VOC compounds both particulate and gaseous.
Kilns All inorganic and most VOC compounds both particulate and gaseous.
Material Handling Operations All inorganic and most VOC compounds both particulate and gaseous.
Gas Cylinders All inorganic and most VOC compounds both particulate and gaseous.
Incinerators and Thermal Oxidizers All inorganic and most VOC compounds both particulate and gaseous.
Calciners Nitrogen Oxides
Fibre Optic manufacture HCl abatement & SiO2 fine particulate (<0.5 µm) removal
Uranium Processing UO2 particulate, NH4NO3 aerosols & Ammonia

Metals and Mineral Products

Emission Source

Pollutants Removed

Kilns Particulate and acid gases
Gold Smelting Clorine abatement & Metallic Chlorides fume removal (aerosols)
Scarfing Operations Particulate
Smelting Furnaces Particulate, Sulfur Dioxide and Nitrogen Oxide
Fiberglass Processing Particulate and odors
Metal Pickling and Cleaning Acid gases, Alkali mists and nitrogen oxides
Electrogalvanizing Process Acid and Alkali mists
Acid Roasting Particulate Matter & Sulphuric Acid
Roasters Particulate and acid gases
Metal Ore Processing and Pelletizing Operations Particulate
Manganese Sinter Plant Particulate abatement (fine and abrasive)
Shale Oil Plant Retrofit of venturi scrubbers to enhance SO2, organic odour & fine particulate abatement
Metal Refining SO2, NH4HSO3 aerosols & NH3 removal

Food & Byproducts

Emission Source

Pollutants Removed

Product Drying Particulate and odors
General Processing Acid gases, Particulate Matter etc
Rendering Operations Odor and particulate control
Animal Feed Processing Particulate and odor control

Waste Treatment

Emission Source

Pollutants Removed

Hazardous Waste Treatment Incinerators Particulate and acid gases including heavy metals, Dioxin and Furans
Pyrolysis & Gasification Tars, SOx, NOx, Dust
Thermal Oxidizers and Pathological Waste Sox, Particulate Matter
Water Sources VOC Stripping
Wastewater Treatment Hydrogen Sulfide, Ammonia, Mercaptans and odours
Boiler Plant (heavy oil fired) SO2 abatement, particulate removal (soot)   & heat recovery

Power & Energy

Emission Source

Pollutants Removed

Boilers and Combustion Sources Flyash, Sulfur Dioxide and Nitrogen Oxides
Synfuels Production Particulate and Ethanol
Wood Burning Power Generation Plant  Heat Recovery, SO2 & fine particulate abatement

Pulp, Paper and Wood Products

Emission Source

Pollutants Removed

Lime Sludge Kiln Lime Dust Removal and Sulfur reduction
Lime Storage and Slaker Lime Dust
Particle Board Drying VOC, Haze, and Particulate
Power and Recovery Boilers Sulfur Dioxide removal
Bleaching Operations Chlorine, Chlorine Dioxide, Ozone and Methanol
Brown Stock Washers Sulfur and Methanol
Carbon Capture and Reuse CO2 and Particulate
Distillery Haze, VOC and Particulate Matter Removal
Plywood and Wood Product Ovens Phenol Formaldehyde and Particulate

Application Examples & Case Studies

Gas Absorption:
Case Study 10 | Case Study 11

Simultaneous Gas Absorption and Particulate Removal :
Case Study 2 | Case Study 3 | Case Study 16

Simultaneous Gas Absorption, Particulate Removal & Heat Recovery:
Case Study 17 | Case Study 30 | Case Study 37

Particulate Control:
Case Study 1 | Case Study 7 | Case Study 30 | Case Study 37 | Case Study 12/13 | Case Study 14 |
Case Study 15

Fine Aerosol Removal:
Case Study 2 | Case Study 15 | Case Study 16 | Case Study 12 & 13 | Case Study 36

Heat Recovery:
Case Study 37 | Case Study 30

Biogas, Pyrolysis & Gasification:
Case Study 19 | Case Study 20

Odour Control:
Case Study 4

Haze & Plume Removal:
Case Study 4 | Case Study 8 | Case Study 9 | Case Study 15

Byproduct Production/Recovery:
Case Study 5 | Case Study 33

CO2 Capture:
Case Study 32 | Case Study 33 | Case Study 34 | Case Study 35

VOC removal from Ground water:
Case Study 38 | Case Study 39